Year 10 Paper 6: Full Topic Review
Covers energy stores and transfers, energy resources and efficiency, electrical circuits, domestic electricity and power, the particle model of matter, atomic structure, and forces and motion.
Year 10 follows a typical teaching order. No exam board defines what belongs to Year 10, and schools sequence the course differently. Check it against your own scheme of work before using it to decide what a class has covered.
Questions
Question 1 [4 marks]
Atomic Structure and Radioactivity
A sample of a radioactive isotope has an initial net count rate of 800 counts per minute, after background radiation has been subtracted. The detector conditions remain unchanged. The isotope has a half-life of 6 hours.
Calculate the net count rate after 18 hours, and state what is meant by half-life.
Question 2 [4 marks]
Energy Resources and Efficiency
An electric drone motor is supplied with 150 W of electrical power. The motor has an efficiency of 68%.
Calculate the useful power output of the motor transferred to the drone's propellers, and the power that is wasted.
Question 3 [4 marks]
Electrical Circuits and Components
A student investigates how the resistance of a filament lamp changes as the current through it increases, by plotting a current against potential difference graph.
Describe the shape of the current against potential difference graph for a filament lamp, and explain why the resistance changes as described.
Question 4 [5 marks]
Forces, Motion and Newton's Laws
A tractor pulls a trailer using a driving force of 3200 N. Friction and air resistance act on the trailer with a total resistive force of 800 N in the opposite direction. The trailer has a mass of 1200 kg.
Calculate the resultant force on the trailer, and its acceleration.
Question 5 [5 marks]
Domestic Electricity and Power
A hairdryer transfers 276,000 J of energy electrically in 4 minutes. The hairdryer is connected to a 230 V supply.
Calculate the current through the hairdryer.
Question 6 [5 marks]
Energy Stores, Transfers and Conservation
An electric fan heater has a power rating of 2000 W and is switched on for 10 minutes. In this time, 900,000 J of the energy supplied is usefully transferred to the thermal energy store of the room; the rest is wasted, transferred outside the room rather than heating it.
Calculate the total energy supplied to the heater in this time, the energy that is wasted, and the efficiency of the heater as a percentage.
Question 7 [5 marks]
Domestic Electricity and Power
Electricity costs 28p per kWh. An electric oven draws a constant electrical input power of 2.5 kW and is used for 45 minutes.
Calculate the energy transferred by the oven in kWh, and the cost of using the oven for this time.
Question 8 [6 marks]
Energy Stores, Transfers and Conservation
An immersion heater rated at 2100 W is used to heat 3 kg of water, initially at 18 deg C, for 150 s. The heater is only 80% efficient; the rest of the input energy is lost to the surroundings rather than heating the water. The specific heat capacity of water is 4200 J/kg deg C.
Calculate the total energy supplied to the heater, the useful energy transferred to the water, and hence the final temperature of the water, assuming no further heat loss from the water.
Question 9 [6 marks]
Atomic Structure and Radioactivity
A worker at a nuclear power station may be exposed to radiation both from external sources and from radioactive dust.
Explain why internal contamination can be particularly hazardous compared with irradiation from an external source, especially for alpha-emitting material. Describe two safety measures used at nuclear power stations to reduce contamination risk, and explain how at least one works.
Question 10 [6 marks]
Energy Stores, Transfers and Conservation
A car engine is supplied with 3600 kJ of chemical energy from its fuel every minute. Of this, 900 kJ is usefully transferred to the kinetic energy store of the car, and the rest is wasted, mainly dissipated as heat and sound.
Calculate the efficiency of the engine as a percentage. Engineers then improve the engine so that 1080 kJ is usefully transferred for the same 3600 kJ of fuel energy supplied each minute. Calculate the new efficiency, and state by how many percentage points the efficiency has improved.
Question 11 [6 marks]
Forces, Motion and Newton's Laws
A train accelerates uniformly from 15 m/s to 35 m/s over a distance of 1000 m.
Calculate the acceleration of the train, and the time this acceleration takes.
Question 12 [6 marks]
Domestic Electricity and Power
A kettle is rated at 230 V, 2760 W. Fuses are available in 3 A, 5 A and 13 A ratings.
Calculate the normal operating current of the kettle, and determine which of the available fuses should be fitted. Explain why the chosen fuse rating should be only a little higher than the normal operating current, rather than much higher.
Question 13 [6 marks]
Forces, Motion and Newton's Laws
A lorry accelerates uniformly from 10 m/s to 22 m/s over a distance of 400 m.
Calculate the acceleration of the lorry, and the time this acceleration takes.
Question 14 [6 marks]
Energy Resources and Efficiency
A school replaces an old gas boiler, which has an efficiency of 72%, with a new gas boiler of the same power rating that has an efficiency of 90%. Both boilers transfer 500,000 kJ of chemical energy from burning gas each day.
Calculate the useful heating energy transferred each day by the old boiler and by the new boiler, then calculate the extra useful energy the new boiler provides per day for the same amount of gas used.
Question 15 [6 marks]
Particle Model of Matter
A gas syringe contains a fixed mass of gas at a pressure of 1.05 x 10^5 Pa and a volume of 4.8 x 10^-5 m^3. The gas is slowly expanded at constant temperature until its pressure falls to 6.0 x 10^4 Pa.
Calculate the new volume of the gas, and explain, using the particle model, why the pressure falls as the volume increases at constant temperature.
Model solutions
| Question 1[4 marks] | |
|---|---|
| Answer or working | Marks |
| number of half-lives elapsed = 18 / 6 = 3 | M1 |
| halving the net count rate three times: 800, then 400, then 200, then 100 | M1 |
| net count rate = 100 counts per minute | A1 |
| stating half-life is the time taken for the number of undecayed parent nuclei, mass of the parent isotope remaining, or activity to halve; accept background-corrected count rate halving with unchanged detector conditions | A1 |
| Final answer: 100 counts per minute. Half-life is the time taken for the number of undecayed parent nuclei, or their activity, to halve. | |
| Question 2[4 marks] | |
|---|---|
| Answer or working | Marks |
| useful power output = efficiency x total power input | M1 |
| substituting 0.68 x 150 | M1 |
| useful power output = 102 W | A1 |
| wasted power = 150 - 102 = 48 W | A1 |
| Final answer: Useful power output = 102 W; wasted power = 48 W. | |
| Question 3[4 marks] | |
|---|---|
| Answer or working | Marks |
| the graph starts as a straight line through the origin and then curves, becoming shallower (the gradient decreases) as the current increases | B1 |
| this shows that the resistance of the filament increases as the current, and its temperature, increases | B1 |
| explaining that as more current flows, the filament gets hotter | B1 |
| explaining the increased temperature makes it harder for charge to flow through the filament, because the ions in the filament vibrate more and collide with the charge carriers more often | B1 |
| Final answer: The I-V graph passes through the origin, is approximately straight at small potential differences, then curves and becomes shallower. This indicates increasing resistance. Current heats the filament; its ions vibrate more strongly and scatter electrons more often, increasing resistance. | |
| Question 4[5 marks] | |
|---|---|
| Answer or working | Marks |
| resultant force = driving force - resistive forces = 3200 - 800 | M1 |
| resultant force = 2400 N | A1 |
| acceleration = resultant force / mass | M1 |
| substituting 2400 / 1200 | M1 |
| acceleration = 2 m/s^2 | A1 |
| Final answer: Resultant force = 2400 N; acceleration = 2 m/s^2. | |
| Question 5[5 marks] | |
|---|---|
| Answer or working | Marks |
| time = 4 x 60 = 240 s | M1 |
| power = energy transferred / time | M1 |
| power = 276000 / 240 = 1150 W | A1 |
| current = power / potential difference | M1 |
| current = 1150 / 230 = 5 A | A1 |
| Final answer: 5 A | |
| Question 6[5 marks] | |
|---|---|
| Answer or working | Marks |
| total input energy = power x time, using time = 10 x 60 = 600 s | M1 |
| total input energy = 2000 x 600 = 1,200,000 J | A1 |
| wasted energy = total input energy - useful output energy | M1 |
| wasted energy = 1200000 - 900000 = 300,000 J | A1 |
| efficiency = useful output energy / total input energy = 900000 / 1200000 = 0.75 (75%) | B1 |
| Final answer: Total input energy = 1,200,000 J; wasted energy = 300,000 J; efficiency = 0.75 (75%). | |
| Question 7[5 marks] | |
|---|---|
| Answer or working | Marks |
| time = 45 / 60 (= 0.75 hours) | M1 |
| energy transferred = power x time = 2.5 x 0.75 | M1 |
| energy transferred = 1.875 kWh | A1 |
| cost = energy transferred x cost per kWh = 1.875 x 28 | M1 |
| cost = 52.5 p (about 53p) | A1 |
| Final answer: Energy transferred = 1.875 kWh; cost = 52.5p (about 53p). | |
| Question 8[6 marks] | |
|---|---|
| Answer or working | Marks |
| total input energy = power x time = 2100 x 150 | M1 |
| total input energy = 315000 J | A1 |
| useful energy transferred to the water = efficiency x total input energy = 0.8 x 315000 | M1 |
| useful energy = 252000 J | A1 |
| rearranging useful energy = m c (change in temperature) to change in temperature = 252000 / (3 x 4200) | M1 |
| change in temperature = 20 deg C, so final temperature = 18 + 20 = 38 deg C | A1 |
| Final answer: Total input energy = 315000 J; useful energy = 252000 J; final temperature of the water = 38 deg C. | |
| Question 9[6 marks] | |
|---|---|
| Answer or working | Marks |
| stating contamination means radioactive material is on or in the body, continuing to expose the person for as long as it remains there | B1 |
| stating irradiation from an external source, in contrast, stops as soon as the person leaves the source or it is shielded/removed | B1 |
| explaining that alpha radiation, although only weakly penetrating from outside the body, is strongly ionising and can do more damage if the emitting material is inside the body, close to living cells, than it could from outside | B1 |
| one suitable measure, such as protective clothing/respirators preventing dust inhalation or deposition, or containment and controlled ventilation | B1 |
| a second distinct suitable measure, such as contamination monitoring followed by decontamination before leaving controlled areas; dosimetry alone does not prevent contamination | B1 |
| explaining how at least one measure prevents radioactive material getting onto or into the body, or removes it to limit ongoing exposure | B1 |
| Final answer: Contamination leaves radioactive material on or in the body, causing exposure for as long as it remains. External irradiation stops when the source is removed or shielded. Alpha radiation has low penetration externally but is strongly ionising, so an internal alpha emitter close to living cells can cause substantial damage. Protective clothing and respirators limit deposition and inhalation; containment and controlled ventilation limit the spread of radioactive dust. Monitoring followed by decontamination is also valid. | |
| Question 10[6 marks] | |
|---|---|
| Answer or working | Marks |
| original efficiency = useful output energy transfer / total input energy transfer | M1 |
| substituting 900 / 3600 | M1 |
| original efficiency = 25% | A1 |
| new efficiency = 1080 / 3600 | M1 |
| new efficiency = 30% | A1 |
| stating the efficiency has improved by 5 percentage points | B1 |
| Final answer: Original efficiency = 25%; new efficiency = 30%; an improvement of 5 percentage points. | |
| Question 11[6 marks] | |
|---|---|
| Answer or working | Marks |
| using v^2 = u^2 + 2 a s with v = 35, u = 15, s = 1000 | M1 |
| rearranging to a = (v^2 - u^2) / (2s) = (35^2 - 15^2) / (2 x 1000) | M1 |
| acceleration = 0.5 m/s^2 | A1 |
| using v = u + a t, rearranged to t = (v - u) / a | M1 |
| substituting (35 - 15) / 0.5 | M1 |
| time = 40 s | A1 |
| Final answer: Acceleration = 0.5 m/s^2; time taken = 40 s. | |
| Question 12[6 marks] | |
|---|---|
| Answer or working | Marks |
| current = power / potential difference | M1 |
| substituting 2760 / 230 | M1 |
| current = 12 A | A1 |
| selecting the 13 A fuse, because it is the only rating higher than the normal operating current (a 5 A fuse would blow during normal use) | B1 |
| explaining the fuse rating should be only a little higher than the normal operating current so that it still blows quickly if a fault causes the current to become dangerously large | B1 |
| explaining that a sustained excessive current heats the wiring and can damage insulation or cause a fire | B1 |
| Final answer: Current = 2760 / 230 = 12 A. Choose the 13 A fuse, the lowest available rating above normal current. It permits normal operation but disconnects if current becomes excessive. A much higher rating can allow an overload to persist, heating the wiring and potentially damaging insulation or causing a fire. | |
| Question 13[6 marks] | |
|---|---|
| Answer or working | Marks |
| using v^2 = u^2 + 2 a s with v = 22, u = 10, s = 400 | M1 |
| rearranging to a = (v^2 - u^2) / (2s) = (22^2 - 10^2) / (2 x 400) | M1 |
| acceleration = 0.48 m/s^2 | A1 |
| using v = u + a t, rearranged to t = (v - u) / a | M1 |
| substituting (22 - 10) / 0.48 | M1 |
| time = 25 s | A1 |
| Final answer: Acceleration = 0.48 m/s^2; time taken = 25 s. | |
| Question 14[6 marks] | |
|---|---|
| Answer or working | Marks |
| useful energy from old boiler = efficiency x total input energy = 0.72 x 500000 | M1 |
| old boiler useful energy = 360000 kJ | A1 |
| useful energy from new boiler = 0.90 x 500000 | M1 |
| new boiler useful energy = 450000 kJ | A1 |
| extra useful energy = 450000 - 360000 | M1 |
| extra useful energy = 90000 kJ | A1 |
| Final answer: Old boiler: 360000 kJ useful per day; new boiler: 450000 kJ useful per day; the new boiler provides 90000 kJ more useful heating energy per day for the same gas used. | |
| Question 15[6 marks] | |
|---|---|
| Answer or working | Marks |
| using pressure x volume = constant, at constant temperature | M1 |
| substituting p1 V1 = p2 V2, i.e. 1.05 x 10^5 x 4.8 x 10^-5 = 6.0 x 10^4 x V2 | M1 |
| p1 V1 = 5.04 (J) | A1 |
| rearranging to V2 = 5.04 / (6.0 x 10^4) | M1 |
| new volume = 8.4 x 10^-5 m^3 | A1 |
| explaining that at constant temperature average particle speed is unchanged, but the larger volume has a lower number density and fewer collisions per unit wall area per second, decreasing pressure. | B1 |
| Final answer: 8.4 x 10^-5 m^3. At constant temperature average particle speed is unchanged, but the larger volume has a lower number density and fewer collisions per unit wall area per second, decreasing pressure. | |