Worked question 15 - Mains Electricity and Circuit Wiring Safety
Answer and mark scheme
Question 15
| Credit | Answer or working |
|---|---|
| B1 | internal fuse on mains side protects the charger and wiring from excessive current drawn from the mains due to a fault in the charger, preventing overheating and fire |
| B1 | it protects the mains supply and user by disconnecting the high-voltage side if a fault causes a short or overload, limiting damage and reducing shock/fire risk |
| B1 | the low-voltage 2 A rating does not limit mains-side current directly because transformation changes voltage and current; a mains fuse ensures faults on either side cannot cause unsafe mains currents |
| B1 | explicit statement that the fuse protects against internal short circuits, earth faults or component failures that would otherwise cause excessive heating or fire risk |
- Answer: The mains-side internal fuse stops excessive current from the 230 V supply if the charger develops a fault, protecting the charger and cable from overheating and preventing fire, and it disconnects the mains to reduce shock risk. The 2 A low-voltage limit does not prevent mains-side faults, so a mains fuse is needed to protect against internal shorts, earth faults and overloads.