Timber and manufactured boards - Worksheets, Questions and Revision
9 original exam-style questions - 4 pages of questions with a full mark scheme - free printable PDF.
Timber and manufactured boards revision guideMore GCSE Design and Technology practice
This topic is chapter 2 of GCSE Design and Technology Topic Workbook 1 and chapter 2 of GCSE Design and Technology 10-Minute Tests.
1.2 Timber and manufactured boards
Question 1
- Select dowelled butt joint and relate it to both limits: 280 N ≥ 250 N and 9 ≤ 12 minutes.B1
- Reject plain butt joint because its 180 N failure load is below 250 N.B1
- Reject mortise and tenon because 18 minutes exceeds 12 minutes, even though its load result passes.B1
- One appropriate assembly control with purpose: dowelling jig/accurate marking for matching holes; dry assembly to check fit before glue; or clamp/check diagonals/use a square to hold the corner square during curing. Accept another valid control linked to its purpose. Do not credit a named tool alone.B1
- Answer: Choose the dowelled butt joint: 280 N exceeds 250 N and 9 minutes is within 12 minutes. The plain butt joint fails the load requirement (180 N). The mortise and tenon fails the time limit (18 minutes). Use a dowelling jig to align matching holes so the dowels and faces fit accurately; a suitable alternative is to clamp square during adhesive curing.
Question 2
- Choose V/clear varnish, linked to both visible grain and passing the splash test after curing.B1
- Reject O/oil because it fails the stated splash test.B1
- Reject P/opaque paint because it hides the grain.B1
- One suitable preparation step with purpose: sand with the grain to reduce visible cross-grain scratches; remove dust for a clean coating; or ensure timber is dry and clean for adhesion. Accept another sound surface preparation step linked to finish quality. No credit for an unsupported cost advantage.B1
- Answer: Choose V/clear varnish, which retains visible grain and passes the splash test after curing. Reject O because it fails the splash test; reject P because it hides the grain. Sand with the grain and remove dust to obtain a clean, smooth surface without trapped dust or conspicuous scratches.
Question 3
- Select P/exterior plywood and explain that I/interior MDF fails the damp-cycle requirement (3.2 mm > 1.0 mm); P passes at 0.6 mm. The cheaper kit I must not be accepted on cost alone.B1
- Method for total cost of selected system: kit cost + £6 for removable screw system + £6 for exterior finish. Allow follow-through for a different selected kit.M1
- £36 total for P with screws and F, within £38.A1
- Reject T because £28 + £6 + £6 = £40, exceeding £38. Accept equivalent comparison showing it is £2 over budget.B1
- Screws into replaceable blocks allow dismantling/repair, while permanent bonding fails this requirement.B1
- Finish F has evidence for rain exposure; G is unsuitable for outdoor rain. State coating all faces and edges plus annual inspection and repair to maintain protection. Accept equivalent wording describing the complete specified finishing and maintenance system.B1
- Answer: Choose P, screws into replaceable blocks and finish F. Total = £24 + £6 + £6 = £36, within £38. P also meets the thickness increase limit (0.6 mm ≤ 1.0 mm). I fails the damp-cycle limit because 3.2 mm > 1.0 mm. T would cost £28 + £6 + £6 = £40, exceeding £38. Screws permit dismantling for repair; permanently bonded joints do not. Finish F is supported for rain exposure, unlike G: coat all faces and edges and inspect/repair the coating annually.
Question 4
- Grain/fibres running along the length of the handle, parallel to the pull.B1
- Links this orientation to the higher measured failure load: 820 N rather than 190 N. Accept the equivalent comparison without both figures.B1
- Large knot interrupts/deflects fibres or creates local weakness, linked to increased splitting or failure risk. Accept a loose knot could fall out and leave a weakened section. Do not accept that every knot always causes failure.B1
- Answer: Run the grain along the 240 mm length. The supplied batch withstood 820 N parallel to the grain compared with 190 N across it. A large knot can interrupt or deflect the grain, creating a weak area where the handle may split or fail.
Question 5
- Method for width: 250 x (1 - 2.0/100), or finds 5 mm reduction then subtracts from 250.M1
- Final width 245 mm, with unit. Accept 245.0 mm.A1
- Method for length: 600 x (1 - 0.1/100), or finds 0.6 mm reduction then subtracts from 600.M1
- Final length 599.4 mm, with unit.A1
- Answer: Width = 250 - (250 x 2.0 / 100) = 245 mm. Length = 600 - (600 x 0.1 / 100) = 599.4 mm.
Question 6
- Method: (560 - 500)/500 x 100. Accept 60/500 x 100.M1
- 12%, with percentage unit.A1
- Does not meet specification because 12% is above the 10% maximum.B1
- Continue controlled drying/conditioning and recheck before final sizing, linked to reaching the specified moisture range or reducing subsequent shrinkage/fit problems. Accept delay final sizing while the batch dries and monitor moisture. Do not accept merely oven-dry the whole batch to 0%.B1
- Answer: Moisture content = ((560 - 500)/500) x 100 = 12%. The batch is above the 10% maximum. Continue controlled drying/conditioning and recheck until within 8-10% before final sizing, reducing the risk of later shrinkage affecting the fit.
Question 7
- Select M/MDF as the cheapest compliant sample.B1
- Justifies compliance using both 4 mm ≤ 5 mm and £10 ≤ £16; accept equivalent words.B1
- Reject C/chipboard because its 8 mm deflection exceeds 5 mm, despite the lower price.B1
- Method for saving between the two compliant samples: £15 - £10.M1
- £5 saving. Accept a correct standalone £5 for this accuracy mark; do not require the words saving.A1
- Answer: Choose M. Its 4 mm deflection is within 5 mm and its £10 cost is within £16. Reject C because 8 mm exceeds 5 mm. P also complies, but M saves £15 - £10 = £5.
Question 8
- Method: divides 2400 by (580 + 3), or compares multiples of 583 with 2400.M1
- Four complete rails per length; rounds down or shows 2332 ≤ 2400 < 2915.A1
- Method for cost: number of lengths = ceiling(8/4) = 2, then 2 x £18. Allow follow-through from a positive whole-number yield if whole stock lengths are rounded up correctly.M1
- £36 minimum total purchase cost.A1
- Answer: 2400/583 = 4.1166..., so four complete rails fit in one length (4 x 583 = 2332 mm; five need 2915 mm). Eight rails need 8/4 = 2 stock lengths. Total purchase cost = 2 x £18 = £36.
Question 9
- Method: 300 + (300 x 1.5/100), or 300 x 1.015.M1
- 304.5 mm expanded width, with unit.A1
- A floating panel retained in grooves, with expansion clearance and edges free of glue. Accept an equivalent arrangement using retaining beads and clearance if it still securely retains the panel and permits sideways movement.B1
- Rigid edge gluing restrains expansion, causing stress that could split/buckle the panel or open frame joints. Accept any valid linked failure mechanism; do not credit merely saying water dissolves glue.B1
- Answer: Expanded width = 300 x 1.015 = 304.5 mm, which fits within the 305 mm space between groove bottoms. Retain the panel in grooves with sufficient expansion clearance and without gluing its edges to the frame, so it can float. Rigid edge gluing could restrain expansion and split/buckle the panel or force frame joints apart.
Mark your answers
Check answers without an account. Some answers can be checked automatically; use the mark scheme to mark the rest.