Show working for calculations. Unless stated otherwise, all stated tolerance limits are inclusive. Use the units given and distinguish a result for an inspected sample from a claim about every unit. Credit equivalent valid calculation methods and justified inspection or process improvements; award each distinct achievement only once.
1
A laser-cut acrylic panel has a slot specified as 20.0 mm ± 0.3 mm. Both tolerance limits are included. State the smallest and largest acceptable slot widths.
(Total for Question 1 is 2 marks)
2
An injection-moulded clip thickness is specified as 2.40 mm ± 0.08 mm, inclusive. The current calliper reads to the nearest 0.1 mm. For this comparison, assume ideal rounding and no other measurement error. The table gives two actual thicknesses. State the acceptable range. Use the table to explain why the calliper cannot reliably distinguish conformity near a limit, and suggest a more suitable instrument and one check on its use.
Clip
Actual thickness (mm)
A
2.31
B
2.34
(Total for Question 2 is 4 marks)
3
A batch of 200 birch-plywood panels has a width specification of 300 mm ± 1 mm, inclusive. A stratified sample of 20 panels from different positions in the batch gives the measurements below. State the acceptable range, calculate the sample defective percentage and recommend a next inspection step justified by this evidence and its limits.
Measured width (mm)
Number of sampled panels
298
1
299
4
300
10
301
4
302
1
(Total for Question 3 is 4 marks)
4
A small workshop finds that laser-cut acrylic covers sometimes exceed a 100.0 mm ± 0.5 mm width limit (inclusive). Records show the errors cluster on one machine after its lens is changed. Propose a justified process improvement and a way to check whether it works, including how to treat boundary measurements.
(Total for Question 4 is 4 marks)
5
A batch of aluminium pins has a diameter specification of 8.00 mm ± 0.05 mm, inclusive. The table records five inspected pins. State the acceptable range, identify each conforming measurement and state how many inspected pins fail.
Pin
Measured diameter (mm)
A
7.94
B
7.95
C
8.00
D
8.05
E
8.06
(Total for Question 5 is 3 marks)
6
A plywood jig plate must be 120 mm ± 1 mm wide, inclusive. A measurement is 121 mm. Is it acceptable? Explain using the boundary rule.
(Total for Question 6 is 2 marks)
7
A turned brass bush has an outside diameter of 14.0 mm ± 0.2 mm and an inside diameter of 10.0 mm ± 0.1 mm. Both limits are included. Find the minimum and maximum wall thickness, assuming concentric diameters.
(Total for Question 7 is 3 marks)
8
A 0.75 m steel rail is specified as 750 mm ± 2 mm, inclusive. Convert both acceptable limits into metres.
(Total for Question 8 is 2 marks)
9
A plastic latch opening is specified as 32.0 mm ± 0.4 mm, inclusive. The table records four inspected openings. Calculate the proportion of these four that are defective, as a percentage.
Latch
Measured opening width (mm)
A
31.6
B
31.7
C
32.4
D
32.5
(Total for Question 9 is 3 marks)
10
A batch of 40 recycled-plastic spacers is measured against a 5.0 mm ± 0.2 mm thickness specification, inclusive. The table summarises all measurements in this batch. Calculate the defective proportion as a fraction and percentage, and state one limitation when applying this result to future production.
Measured thickness (mm)
Number of spacers
4.7
2
4.8
7
5.0
20
5.2
8
5.3
3
(Total for Question 10 is 3 marks)
11
A laser-cut bracket has a 24.0 mm ± 0.2 mm slot, with both limits included. A mating tab is 23.3 mm wide. Calculate the minimum and maximum clearance and decide whether the fit is guaranteed to have clearance throughout the allowed slot range. Treat the tab width as fixed and clearance as slot width minus tab width.
(Total for Question 11 is 3 marks)
12
A dowel and hole have these specifications: hole diameter 10.0 mm ± 0.1 mm and dowel diameter 9.8 mm ± 0.1 mm, with all limits included. Calculate the smallest and largest possible diametral clearance (hole diameter minus dowel diameter). State whether a clearance fit is guaranteed for conforming parts and whether strictly positive clearance is guaranteed. A clearance fit permits zero clearance at a limiting size.
(Total for Question 12 is 4 marks)
Mark scheme · 1.10 Tolerances and Quality Control
Question 1
lower limit = 20.0 - 0.3 = 19.7 mmB1
upper limit = 20.0 + 0.3 = 20.3 mmB1
Answer: 19.7 mm to 20.3 mm inclusive
Question 2
acceptable range is 2.32 mm to 2.48 mmB1
2.31 mm is below the lower limit but 2.34 mm is within tolerance; both round to 2.3 mm on this calliper, so its reading cannot distinguish their conformity (or another valid rounding example near a limit)B1
use a calibrated instrument with finer resolution and suitable accuracy for the limits, such as a micrometer reading to 0.01 mm; credit an equivalent suitable instrumentB1
check zero/calibration against a known reference, or repeat measurements at consistent points with controlled measuring force; credit an equivalent valid checkB1
Answer: 2.32 mm to 2.48 mm inclusive. The 2.31 mm clip fails and the 2.34 mm clip conforms, but both display 2.3 mm. Use a calibrated micrometer reading to 0.01 mm with suitable accuracy, and check its zero against a reference.
Question 3
acceptable interval is 299 mm to 301 mm inclusiveB1
1 + 1 = 2 defective sampled panels; 2 / 20 x 100 = 10% defective in the sampleM1
recommend inspecting more panels from across the batch, or every remaining panel, using a calibrated gauge; credit an equivalent suitable inspection stepB1
justify further inspection because the sample contains defects and the uninspected panels may also contain defects; the sample does not establish the exact defective total among all 200 panelsB1
Answer: 299 mm to 301 mm inclusive; 10% of the sample was defective. Inspect the remaining panels with a calibrated gauge because defects were found and the sample cannot establish how many of the uninspected panels conform.
Question 4
check and reset focus/alignment after lens changes, or verify and correct the cutting setup using a first-off piece, because errors cluster after that event; credit an equivalent improvement linked to the evidenceB1
use a calibrated instrument to accept widths from 99.5 mm to 100.5 mm inclusive, including both boundary valuesB1
record measurements from repeated production runs or a suitable sample before and after the changeB1
compare before/after defective proportions against the inclusive limits to assess improvement and investigate any out-of-range result; samples indicate performance but do not prove every unit conformsB1
Answer: Check and reset focus/alignment after lens changes because errors cluster then. Inspect first-off pieces and compare defective proportions from repeated runs before and after the change, accepting 99.5 mm to 100.5 mm inclusive. Investigate failures; samples do not prove every unit conforms.
Question 5
acceptable range is 7.95 mm to 8.05 mm inclusiveB1
7.95 mm, 8.00 mm and 8.05 mm conformB1
7.94 mm and 8.06 mm fail: 2 pinsB1
Answer: Conforming: 7.95, 8.00 and 8.05 mm; 2 fail
Question 6
upper limit is 120 + 1 = 121 mmB1
yes, it is acceptable because the stated boundary is includedB1
Answer: Yes. 121 mm is the included upper limit.
Question 7
minimum wall = (minimum outside - maximum inside) / 2M1
(13.8 - 10.1) / 2 = 1.85 mmA1
maximum wall = (14.2 - 9.9) / 2 = 2.15 mmA1
Answer: Minimum 1.85 mm; maximum 2.15 mm
Question 8
limits are 748 mm and 752 mmM1
divide by 1000: 0.748 m and 0.752 mA1
Answer: 0.748 m to 0.752 m inclusive
Question 9
acceptable interval is 31.6 mm to 32.4 mm inclusiveB1
31.6, 31.7 and 32.4 mm conform; 32.5 mm fails, so 1 of 4 is defectiveM1
1 / 4 x 100 = 25%A1
Answer: 25% defective
Question 10
inclusive limits are 4.8 mm and 5.2 mm; 2 + 3 = 5 defective spacers, so defective fraction = 5 / 40 = 1 / 8 (or an equivalent fraction)M1
1 / 8 x 100 = 12.5%A1
the result describes this inspected batch only; it does not prove every uninspected spacer conformsB1
Answer: 1/8, or 12.5%; this batch result does not establish conformity of every unit
yes, clearance is guaranteed; the minimum is positive at 0.5 mmA1
Answer: Minimum clearance 0.5 mm, maximum 0.9 mm; clearance is guaranteed
Question 12
minimum hole = 9.9 mm and maximum dowel = 9.9 mmM1
minimum clearance = 9.9 - 9.9 = 0.0 mmM1
maximum hole = 10.1 mm and minimum dowel = 9.7 mm; maximum clearance = 0.4 mmM1
yes, a clearance fit is guaranteed for conforming parts because clearance is never negative; strictly positive clearance is not guaranteed because the minimum is 0.0 mmB1
Answer: 0.0 mm to 0.4 mm inclusive. A clearance fit is guaranteed for conforming parts; strictly positive clearance is not guaranteed.
Put this topic and others into one printable pack.
Open the Pack Builder
Worksheets are written for Revision Library and come with a full mark scheme; a few English packs quote an out-of-copyright text, and name it on the page. Exam board names and specification codes say which qualification a pack suits: we are not affiliated with, endorsed by or approved by any exam board, and no past-paper question is reproduced here. Rights queries: hello@revisionlibrary.co.uk