A battery-powered cupboard light uses a light-dependent resistor (LDR), a control circuit and an LED. Identify the input, process and output in this system.
(Total for Question 1 is 3 marks)
2
A fictional buzzer is rated 5 V and 0.12 A. Calculate its power using P = V x I.
(Total for Question 2 is 2 marks)
3
A fictional control board requires 5 V and draws 0.30 A. A regulator is rated to provide 5 V at up to 0.40 A. Decide whether it meets both requirements and explain.
(Total for Question 3 is 2 marks)
4
A fictional automatic plant-watering product must detect soil moisture, switch a 12 V pump drawing 1.4 A, and indicate when watering is active. Available parts: moisture sensor (analogue output, 0 to 3 V); controller (analogue input, 5 V supply); driver X (12 V, 1.0 A maximum); driver Y (12 V, 2.0 A maximum); green LED (2 V, 20 mA). Describe a suitable input-process-output arrangement and choose a suitable pump driver, using the supplied data.
(Total for Question 4 is 4 marks)
5
A fictional desk lamp switches on when its sensor reading is below 300 lux. At 280 lux it switches on; at 340 lux it switches off. State the input, output and the role of the 300 lux value.
(Total for Question 5 is 3 marks)
6
A fictional temperature sensor table gives: 10 C = 1.0 V, 20 C = 2.0 V, 30 C = 3.0 V. State the sensor output voltage at 25 C, assuming a linear change between readings.
(Total for Question 6 is 2 marks)
7
A fictional pressure sensor provides 0.5 V at 0 kPa and 4.5 V at 100 kPa. The controller receives 2.5 V. Assuming a linear response, calculate the pressure.
(Total for Question 7 is 3 marks)
8
A fictional proximity sensor has a reliable operating range of 5 cm to 80 cm. A product must detect a hand at 12 cm. State whether the sensor meets the requirement and justify your answer.
(Total for Question 8 is 2 marks)
9
A fictional controller needs a digital input. A sensor datasheet states: output type = digital; logic low = 0 to 0.8 V; logic high = 2.0 to 5.0 V. The sensor outputs 3.3 V when active. State the logic state and explain.
(Total for Question 9 is 2 marks)
10
A fictional indicator LED is rated at 2.0 V and 15 mA. A 6.0 V supply is used with a series resistor. Calculate the resistor value needed, using R = V / I.
(Total for Question 10 is 3 marks)
11
A fictional fan draws 0.42 A in normal operation. The controller output is rated for a maximum of 0.50 A. Decide whether it can drive the fan directly and justify your decision.
(Total for Question 11 is 2 marks)
12
A fictional motor draws 0.8 A while running and 1.6 A at start-up. A driver is rated for 1.2 A maximum. Choose whether this driver is suitable and justify your choice.
(Total for Question 12 is 2 marks)
Mark scheme · 1.9 Electrical Systems
Question 1
input: LDR sensing light levelB1
process: control circuit compares or uses the sensor signalB1
output: LED producing lightB1
Answer: Input: LDR light sensor. Process: control circuit. Output: LED light.
Question 2
substitution P = 5 x 0.12M1
0.60 WA1
Answer: 0.60 W
Question 3
yes: output voltage matches 5 V requirementB1
0.30 A required is less than 0.40 A capacityB1
Answer: Yes. It supplies the required 5 V and its 0.40 A capacity exceeds the 0.30 A draw.
Question 4
moisture sensor is the input and supplies analogue moisture data to the controller analogue inputB1
controller processes/uses moisture reading to decide when watering is neededB1
controller output switches pump via driver Y; 12 V matches pump and 2.0 A rating exceeds 1.4 AB1
green LED is an output indicator when watering is activeB1
Answer: The moisture sensor is the input to the controller analogue input. The controller processes the reading and switches the pump through driver Y: its 12 V rating matches and its 2.0 A limit exceeds the pump 1.4 A draw. The green LED indicates watering.
Question 5
input is measured light levelB1
output is lamp on/off stateB1
300 lux is the switching thresholdB1
Answer: Input: light level. Output: lamp state. 300 lux is the threshold.
Question 6
recognises 0.1 V per C or interpolates halfway between 2.0 V and 3.0 VM1
2.5 VA1
Answer: 2.5 V
Question 7
voltage change is 4.0 V across 100 kPa, giving 25 kPa per VM1
uses the 2.0 V rise above the 0 kPa outputM1
50 kPaA1
Answer: 50 kPa
Question 8
yes, 12 cm is within the stated 5 cm to 80 cm rangeB1
the sensor is specified to operate reliably at that distanceB1
Answer: Yes. 12 cm is inside its stated reliable range.
Question 9
logic highB1
3.3 V lies within the stated 2.0 V to 5.0 V high rangeB1
Answer: Logic high, because 3.3 V is in the specified high range.
Question 10
resistor voltage = 6.0 - 2.0 = 4.0 VM1
converts current: 15 mA = 0.015 A; uses R = 4.0 / 0.015M1
about 267 ohmA1
Answer: About 267 ohm
Question 11
yes, 0.42 A is below the 0.50 A maximumB1
the stated current rating is not exceededB1
Answer: Yes. The 0.42 A fan current is below the 0.50 A output limit.
Question 12
not suitableB1
start-up current 1.6 A exceeds 1.2 A maximumB1
Answer: Not suitable: the 1.6 A start-up current exceeds its 1.2 A rating.
Put this topic and others into one printable pack.
Open the Pack Builder
Worksheets are written for Revision Library and come with a full mark scheme; a few English packs quote an out-of-copyright text, and name it on the page. Exam board names and specification codes say which qualification a pack suits: we are not affiliated with, endorsed by or approved by any exam board, and no past-paper question is reproduced here. Rights queries: hello@revisionlibrary.co.uk