2.27 Chromatography and Instrumental Analysis
Separating and Identifying Substances
Revision Library resource team
Chemists often need to check how pure a substance is, or work out what is in a mixture. Paper chromatography separates the different substances in a mixture, because they move through the paper at different rates, carried by a solvent. Comparing the distance a spot travels with the distance travelled by the solvent gives an Rf value, which can be compared with reference substances to identify the components of a mixture, such as a food colouring or an ink. Modern laboratories also use instrumental methods of analysis. These use machines, rather than test tubes, and give results that are faster, more sensitive and more accurate than traditional chemical tests, especially when only a very small sample is available. Flame emission spectroscopy is one such instrumental method: it identifies which metal ions are present in a sample, and how concentrated they are, by analysing the light given out when the sample is placed in a flame.
| Component | Percentage of mass |
|---|---|
| Titanium dioxide pigment | 18% |
| Resin (binder) | 45% |
| Solvent | 30% |
| Additives | 7% |
| Metal ion | Wavelength of main line (nm) |
|---|---|
| Lithium, Li+ | 671 |
| Sodium, Na+ | 589 |
| Potassium, K+ | 767 |
| Calcium, Ca2+ | 422 |
The table below shows the Rf value of four reference food dyes, run in the same solvent.
| Dye | Rf value |
|---|---|
| Allura Red AC | 0.30 |
| Sunset Yellow | 0.55 |
| Tartrazine | 0.70 |
| Brilliant Blue | 0.90 |
Describe a method the technician could use to carry out this investigation and obtain valid, comparable results. In your answer, you should refer to how the chromatogram is set up, how it is run, and how the results would be analysed.
| Concentration (mg/dm3) | Peak height (arbitrary units) |
|---|---|
| 2 | 10 |
| 4 | 20 |
| 6 | 30 |
| 8 | 40 |
| 10 | 50 |
| Ink sample | Distance travelled (cm) |
|---|---|
| Ransom note | 6.5 |
| Suspect 1 | 4.0 |
| Suspect 2 | 6.5 |
| Suspect 3 | 8.2 |
| Suspect 4 | 3.0 |
Question 1
- (a) a substance that contains only one element or one compound, with nothing else mixed in, oeB1
- (a) Answer: A pure substance contains only one element or one compound throughout, with no other substance mixed in.
- (b) a mixture that has been designed as a useful product, made by mixing components in carefully measured quantities, oeB1
- (b) Answer: A formulation is a mixture that has been designed as a useful product, with each component present in a carefully measured quantity.
Question 2
- (a) the distance travelled by a spot (solute) divided by the distance travelled by the solvent, measured from the same baseline, oeB1
- (a) Answer: The Rf value is the distance travelled by a spot divided by the distance travelled by the solvent, both measured from the same baseline.
- (b) Rf = distance moved by spot / distance moved by solvent, oeB1
- (b) Answer: Rf = distance moved by spot / distance moved by solvent
Question 3
- (a) component named, e.g. pigment (accept solvent, binder/resin, or additive)B1
- (a) purpose correctly linked to the named component, e.g. pigment gives the paint its colour, oeB1
- (a) Answer: E.g. pigment - gives the paint its colour.
- (b) component named, e.g. the active drug (accept binder, filler, or coating)B1
- (b) purpose correctly linked to the named component, e.g. the active drug produces the medical effect, oeB1
- (b) Answer: E.g. the active drug - produces the medical effect of the tablet.
Question 4
- (a) 5.0 x 0.18, oe correct methodM1
- (a) 0.90 kg cao (allow 900 g)A1
- (a) Answer: 0.90 kg (900 g)
- (b) 5.0 x 0.30, oe correct methodM1
- (b) 1.5 kg caoA1
- (b) Answer: 1.5 kg
Question 5
- (a) Rf = 5.6 / 8.4, oe correct substitution into the Rf equationM1
- (a) 0.67 cao (allow 0.666 to 0.667 before rounding)A1
- (a) Answer: 0.67
Question 6
- (a) pencil is insoluble in the solvent, so it does not dissolve and move up the paper (and so cannot be mistaken for a dye spot); ink would dissolve and run, oeB1
- (a) Answer: Pencil does not dissolve in the solvent, so the baseline stays in place and is not confused with a dye spot; ink would dissolve and run up the paper with the solvent.
- (b) if the solvent covered the baseline, the spots would dissolve directly into the solvent bath rather than being carried up the paper, so no separation would take place, oeB1
- (b) Answer: If the solvent were above the baseline, it would dissolve the spots straight into the solvent instead of carrying them up the paper, so the substances could not be separated.
- (c) it keeps the atmosphere inside the beaker saturated with solvent vapour, which stops the solvent evaporating, so the chromatogram runs consistently/reliably, oeB1
- (c) Answer: The lid keeps the atmosphere inside saturated with solvent vapour, which stops the solvent evaporating and helps give reliable, repeatable results.
Question 7
- (a) any one of: faster than chemical testsB1
- (a) any other one of: more sensitive (can detect very small amounts/low concentrations)B1
- (a) any other one of: more accurate; needs only a very small sample; less reliant on the skill or subjective judgement of the person carrying out the test (accept any three distinct correct advantages)B1
- (a) Answer: Any three of: faster; more sensitive; more accurate; needs a smaller sample; less reliant on the skill or judgement of the analyst.
- (b) the equipment is expensive to buy and maintain, and specially trained staff are needed to operate it and interpret the results, oeB1
- (b) Answer: The equipment is expensive to buy and maintain, and needs trained staff to operate it and interpret the data.
Question 8
- (a) a small sample of the solution is put into a flame, oeB1
- (a) the light given out (emitted) by the flame is passed through a spectroscope, oeB1
- (a) the spectroscope produces a line spectrum, a pattern of coloured lines at specific wavelengths, oeB1
- (a) the line spectrum produced is compared with reference spectra of known ions, to identify which metal ion(s) are present in the sample, oeB1
- (a) Answer: A sample is placed in a flame; the light emitted is passed through a spectroscope, which produces a line spectrum. This spectrum is compared with reference spectra to identify the metal ion(s) present.
Question 9
- (a) sodium, Na+B1
- (a) because the spectrum shows a line at 589 nm, which matches the reference wavelength for sodium, oeB1
- (a) Answer: Sodium (Na+). The line at 589 nm matches the reference emission wavelength for sodium ions.
- (b) the solution contains a mixture of (at least) two different metal ions, oeB1
- (b) sodium ions, Na+ (line at 589 nm), and lithium ions, Li+ (line at 671 nm), are both presentB1
- (b) Answer: The solution is a mixture containing both sodium ions (589 nm) and lithium ions (671 nm).
Question 10
- (a) any one of: it is more accurate/objective, since it does not rely on an observer judging a flame colour by eyeB1
- (a) any other one of: it can also determine the concentration of the ion present, not just confirm which ion is present; it can identify ions in a mixture, even if their flame colours would overlap or mask each other when viewed by eye; it is more sensitive (can detect lower concentrations)B1
- (a) Answer: Any two of: it is more accurate/objective than judging a flame colour by eye; it can determine the concentration of the ion, not just its identity; it can identify ions in a mixture whose flame colours might otherwise be masked or overlap.
Question 11
- (a) distance = Rf x distance moved by solvent = 0.75 x 12.0, oe correct rearrangementM1
- (a) 9.0 cm caoA1
- (a) Answer: 9.0 cm
Question 12
- (a) the sample melts over a range of temperatures (116°C to 121°C) rather than sharply at one exact temperature, oeB1
- (a) a pure substance melts sharply at one fixed temperature (its melting point); here that would be 122°C, oeB1
- (a) so the solid is not pure compound X / it is impure, since it melts over a range and below the known melting point of the pure compound (ecf from the first two marking points)B1
- (a) Answer: The solid is impure. It melts over a range of temperatures (116 to 121°C), and below the known melting point of pure compound X (122°C), instead of sharply at 122°C.
Question 13
- (a) 0.30 (2.7 / 9.0) caoB1
- (a) 0.70 (6.3 / 9.0) caoB1
- (a) 0.90 (8.1 / 9.0) caoB1
- (a) Answer: 0.30, 0.70 and 0.90
- (b) Allura Red AC (Rf 0.30 matches)B1
- (b) Tartrazine (Rf 0.70 matches)B1
- (b) Brilliant Blue (Rf 0.90 matches) (ecf from part a: match whichever Rf values the student calculated to the closest reference dye)B1
- (b) Answer: Allura Red AC, Tartrazine and Brilliant Blue.
- (c) formulation (a mixture)B1
- (c) because it separates into more than one spot on the chromatogram, showing it contains more than one dye, oeB1
- (c) Answer: It is a formulation. It produces three separate spots on the chromatogram, showing it is a mixture of three different dyes rather than one pure substance.
Question 14
- Level 3 A clear, logically ordered method is described, covering setting up the chromatogram, running it correctly, and how the results (Rf values and/or colours, compared with the reference dyes) would be used to identify the dyes present in each squash sample.5-6
- Level 2 The method is partly described, covering some key practical steps, such as setting up or running the chromatogram, but with gaps in either the running of the experiment or the analysis of results. There is some logical structure.3-4
- Level 1 Simple, isolated statements are made about chromatography, with little or no reference to a full practical method or to how the dyes would be identified.1-2
- Level 0 No relevant content.0
- Indicative content:
- draw a baseline in pencil (not pen, as pen ink would dissolve and run), near the bottom of the chromatography paper
- use a fine pipette or capillary tube to place a small spot of each squash sample, and of each reference dye, on the baseline; label each spot
- let each spot dry before adding more solution on top of it, to keep the spots small and concentrated
- pour a shallow layer of solvent into a beaker, to a depth below the pencil baseline
- suspend or hang the paper in the beaker so the baseline sits above the solvent surface (the spots must not be submerged in the solvent)
- cover the beaker with a lid, to keep the atmosphere saturated with solvent vapour and reduce evaporation of the solvent
- leave until the solvent has risen close to the top of the paper, then remove the paper and immediately mark the solvent front in pencil, before it evaporates
- allow the chromatogram to dry, then measure the distance travelled by the solvent front and by each spot, from the baseline
- calculate the Rf value of each spot using Rf = distance moved by spot / distance moved by solvent
- compare the Rf value (and colour) of each spot from a squash sample with the Rf values of the reference dyes run on the same chromatogram, under the same conditions
- a dye is identified as present in a squash sample if a spot's Rf value (and colour) matches a reference dye's Rf value
Question 15
- (a) peak height / concentration calculated for at least two pairs of values, e.g. 10/2 = 5, 20/4 = 5, 30/6 = 5, 40/8 = 5, 50/10 = 5M1
- (a) the ratio is constant (= 5) for every pair of values, so peak height is directly proportional to concentration, oeA1
- (a) Answer: Peak height / concentration = 5 for every pair of values in the table, so peak height is directly proportional to concentration.
- (b) concentration = peak height / 5, oe correct use of the proportional relationship from part a (ft)M1
- (b) 7 mg/dm3 cao (ft)A1
- (b) Answer: 7 mg/dm3
Question 16
- (a) 6.5 / 10.0, oe correct substitutionM1
- (a) 0.65 caoA1
- (a) Answer: 0.65
- (b) Suspect 2B1
- (b) Suspect 2's ink also travelled 6.5 cm, giving the same Rf value (0.65) as the ransom note ink (ecf from part a)B1
- (b) Answer: Suspect 2. Their ink spot also travelled 6.5 cm, giving the same Rf value (0.65) as the ransom note ink.
- (c) an Rf value depends on the solvent used (and other conditions, such as temperature and the type of paper), oeB1
- (c) so Rf values can only be validly compared if they were obtained under identical conditions, e.g. run together on the same chromatogram with the same solvent, oeB1
- (c) Answer: Rf values depend on the solvent (and on conditions such as temperature and paper type), so samples can only be fairly compared if they are run together, under identical conditions.
Question 17
- (a) producing only one spot, in every solvent tested, suggests the powder is likely to be a pure substance rather than a mixture, oeB1
- (a) a mixture would be expected to separate into more than one spot in at least one solvent, since different substances usually move at different rates through the paper, oeB1
- (a) other test: measure the melting point of the powder; a pure substance melts sharply at one exact temperature, rather than over a range, oe (accept boiling point test)B1
- (a) Answer: One spot in every solvent suggests the powder is pure, since a mixture would usually separate into more than one spot in at least one solvent. This could be confirmed with a melting point test: a pure substance melts sharply at a single, fixed temperature.
Question 18
- (a) a contaminated (impure) sample melts over a range of temperatures, usually starting below the true melting point of the pure drug, oeB1
- (a) so if the extracted drug melts over a range, rather than sharply at the known melting point of the pure drug, this shows it is contaminated, oeB1
- (a) Answer: If the extracted drug melts over a range of temperatures, rather than sharply at the known melting point of the pure drug, this shows the sample is contaminated.
- (b) run a sample of the tablet coating alongside reference spots of pure dye X and pure dye Y, on the same chromatogram, using the same solvent, oeB1
- (b) calculate the Rf value(s) of the spot(s) produced by the tablet coating sampleB1
- (b) if the tablet sample produces only one spot, matching the Rf value of dye X, it is not contaminated; a second spot matching the Rf value of dye Y would show contamination, oeB1
- (b) Answer: Run the tablet coating alongside reference spots of dye X and dye Y on the same chromatogram. If only one spot appears, with the same Rf value as dye X, the coating is pure; an extra spot matching dye Y's Rf value would show contamination with dye Y.
- (c) L3 A well-reasoned evaluation is given, covering several advantages of flame emission spectroscopy (such as sensitivity, accuracy and the ability to measure concentration) applied clearly to why this matters for detecting trace metal contamination in tablets, leading to a justified conclusion.5-6
- (c) L2 Some relevant advantages of flame emission spectroscopy are given and applied to the tablet quality-control context, but the answer lacks a balanced evaluation or clear reasoning throughout.3-4
- (c) L1 A simple statement, or a short list, of one or two general points about instrumental methods is given, with little reference to the specific context of quality-controlling tablets for metal contamination.1-2
- (c) L0 No relevant content.0
- (c) Indicative content:
- flame emission spectroscopy is far more sensitive than chemical tests, so it can detect very low (trace) concentrations of metal contamination that a chemical test might miss
- trace contamination is exactly the kind of small-sample, low-concentration analysis that instrumental methods are best suited to
- it is more accurate than chemical tests, which often rely on an analyst's subjective judgement, e.g. judging a colour change or a flame colour by eye
- it can determine the concentration of any contaminating metal ion present, not just confirm its presence, which matters for quality control (a tablet may be within or outside a safe limit)
- results are fast, which suits the high throughput needed in pharmaceutical quality control, where many tablets or batches must be tested
- it can identify more than one metal ion present in a mixture from a single sample or spectrum
- counterbalancing point: the equipment is expensive and requires trained staff, but for a pharmaceutical company this cost is justified by the need for precise, reliable safety data
- conclusion: flame emission spectroscopy is more suitable overall, because trace contamination requires the sensitivity and quantitative concentration data that chemical tests cannot reliably provide
- (c) Answer: Levels of response part, no single correct answer; credit a balanced evaluation covering the high sensitivity of flame emission spectroscopy (able to detect trace/low concentrations of contaminating metal ions), its accuracy compared with chemical tests that rely on an analyst's judgement, its ability to measure the concentration of any contaminant (important for checking against a safety limit), and its speed (suiting high-throughput quality control), balanced against the cost of the equipment and staff training, leading to a justified conclusion. See indicative content.